Leave Your Message
3D SEE Trabecular Acetabular System for Hip Replacement - China Suppliers & Factory Solutions
Hot Products

Product Details

3D SEE Trabecular Acetabular System for Hip Replacement - China Suppliers & Factory Solutions

● Comprehensive Clinical Application
Our advanced hip solutions are specifically designed to tackle conditions such as hip dysplasia (DDH), primary hip replacement, and revision surgeries, catering to diverse surgical requirements. As leading suppliers from China, we ensure our products meet the highest standards of quality and performance.

● Dual Cup-Liner Connection Options
We offer two secure attachment methods that enhance surgical flexibility and stability, making our implants a top choice among factories specializing in orthopedic products.

① Cemented Connection:
Our cemented option allows for precise placement and angle adjustments within a safe zone using HPE bone cement, minimizing the risk of postoperative dislocation and ensuring patient safety.

② Press-Fit Connection:
This feature includes a locking mechanism for secure liner fixation, compatible with HPE-10° and Harmony 10° liners, making it particularly suitable for hip revision surgeries. Trust our China-based factory for reliable solutions that optimize surgical outcomes.

    Mesh&Cage

    Trabecular Acetabular Cup DDH & Standard

    3d-see-trabecular-acetabular-system-1-1
    Screw hole

    Exceptional initial stability:

    DDH: 6 screw holes (for deformity fixation)

    Standard: 3 screw holes (fixed to the posterior superior bone for effective anchoring)

    Revision: "Starry Sky" screw hole—6 dome holes 9 peripheral holes (all Φ 6.0 screw)

    Triple locking mechanism

    Maximize liner-to-cup contact to achieve effective force transmission, minimize micromotion, and reduce debris.

    3d-see-trabecular-acetabular-system-3-1
    3D EBM printing technology

    Excellent biocompatibility;

    No risk of surface delamination, promoting long-term bone growth

    1.08 friction coefficient on trabecular surface

    High surface roughness, increasing friction with host bone for superior initial stability

    Tight press-fit design(1.5mm, single-size rasp)

    Exceptional initial stability

    3d-see-trabecular-acetabular-system-2-1
    75%-80% High porosity

    Achieves reliable bone growth:

    Increases contact with the host bone

    Facilitates cell and blood flow, promoting bone formation

    Reduces elastic modulus, minimizing stress shielding

    3D interconnected porous structure

    Ensuring reliable bone growth

    600-800 µm pore size

    In vivo tests show: 800 μm pore size promotes bone growth

    SEE Trabecular Acetabular Cup -Revision

    4e7dcccd4e9cb8d4088daba15a136703
    "Starry Sky" screw hole

    6 dome holes 9 peripheral holes (all Φ 6.0 screw)

    Providing flexibility during surgery and allowing the surgeon to choose the optimal screw placement

    More suitable for patients with severe acetabular bone defects and irregular acetabular

    Load direction aligns more closely with the body's natural lower limb biomechanics, providing better initial and long-term stability

    b4811bfa8c1619559058f518ff8ebff5
    Streamlined cup thickness

    Preserves more bone while ensuring outer diameter and strength

    Allows for larger femoral heads, improving range of motion, lower dislocation rates, and enhancing stability

    Sizes 48#—74# comprehensively cover all needs for acetabular revision and complex primary replacements

    a3415090502dddae407c56987ed8e461
    Acetabular cup with HXLPE cemented liner

    The acetabular cup can be adjusted based on the specific condition of the acetabulum. Afterward, the cemented liner can be adjusted within a defined "safe zone" to fine-tune anteversion and abduction angles, making revision surgery more flexible and straightforward, while preventing postoperative dislocation

    The highly crosslinked material offers excellent wear resistance and anti-oxidation properties

    3d-see-trabecular-acetabular-system-5
    Hole Cover (threaded)

    Sealing in areas where acetabular screws are not implanted

    Increase acetabular contact area

    Increase overall strength of the acetabular cup

    Prevent leakage of bone cement

    SEE Trabecular Acetabular Cup Revision JCT

    3d-see-trabecular-acetabular-system-6
    "Starry Sky" screw hole design

    The design features 6 evenly distributed peripheral screw holes and 6 dome screw holes, providing flexibility during surgery and allowing the surgeon to more effectively choose screw placement.

    More suitable for patients with severe acetabular bone defects and irregular acetabular shapes

    3D SEE Trabecular Acetabular System

    3d-see-trabecular-acetabular-system-9
    Uniform joint surface morphology

    Ensure that all liner models have the same rotational center position.

    Special Instrumentation

    SEE Trabecular Acetabular Cup (DDH & Standard)

    3D SEE Trabecular Acetabular System (1)
    Specification Outer Diameter Liner Femoral Head
    44 44 44/28 28
    46 46 46/28
    48 48 48/28 28
    50 50 50/28, 50/32 28/32
    52 52 52/28, 52/32, 52/36 28/32/36
    54 54 54/28, 54/32, 54/36
    56 56 56/28, 56/32, 56/36
    58 58 58/28, 58/32, 58/36
    60 60 60/28, 60/32, 60/36
    62 62 62/28, 62/32, 62/36
    64 64 64/28, 64/32, 64/36
    66 66 66/28, 66/32, 66/36

    SEE Trabecular Acetabular Cup (Type I)

    3D SEE Trabecular Acetabular System (2)

    Only for XLWzero Ceramic Liner

    Specification Ceramic Liner Femoral Head
    44 3#-28/36 28
    46 3#-28/36
    48 4#-28/38
    50 5#-32/40 32
    52 6#-32/42
    54 7#-36/44 36
    56 8#-36/46
    58 9#-36/48
    60 10#-36/50
    62 11#-36/52
    64 12#-36/54

    SEE Trabecular Acetabular Cup (Revision)

    3D SEE Trabecular Acetabular System (3)

    Only for Cemented Liner (HPE)

    Specification Outer Diameter Cemented Liner Femoral Head Screw
    48 48 48/28 28 FD-8
    50 50 50/32 32
    52 52 52/32
    54 54 54/32
    56 56 56/36 36
    58 58 58/36
    60 60 60/36
    62 62 62/36
    64 64 64/36
    66 66 66/36

    Trabecular Acetabular Cup (Revision JCT)

    3D SEE Trabecular Acetabular System (4)
    Specification Outer Diameter Liner (Standard) Liner (10°) Femoral Head
    48 48 48/28 48/28; 48/32 28/32/36
    50 50 50/28; 50/32 50/28; 50/32
    52 52 52/32; 52/36 52/28; 52/32
    54 54 54/32; 54/36 54/28; 54/32
    56 56 56/32; 56/36 56/28; 56/32
    58 58 58/32; 58/36 58/28; 58/32
    60 60 60/32; 60/36 60/28; 60/32
    62 62 62/32; 62/36 62/28; 62/32
    64 64 64/32; 64/36 64/28; 64/32
    66 66 66/32; 66/36 66/28; 66/32

    Frequently Asked Questions (FAQ)

    What are the primary advantages of 3D EBM printing technology in this acetabular system?
    The 3D Electron Beam Melting (EBM) printing technology ensures superior biocompatibility and structurally eliminates the risk of surface delamination, creating an optimal surface for long-term biological bone integration.
    How does the 75%-80% porosity contribute to bone ingrowth?
    High porosity increases the surface contact area with the host bone, promotes the flow of blood and osteogenic cells, and reduces the elastic modulus to minimize the risk of stress shielding.
    What is the functional design behind the "Starry Sky" screw hole pattern?
    The "Starry Sky" pattern incorporates multiple dome and peripheral screw holes that provide surgeons with maximum flexibility in selecting screw placement, specifically accommodating severe or irregular acetabular bone defects while aligning with lower limb biomechanics.
    How does the triple locking mechanism work?
    The triple locking mechanism maximizes contact between the cup and the liner to enhance force transmission efficiency, lower micromotion between components, and effectively reduce wear debris generation.
    What is the purpose of the threaded Hole Cover?
    Threaded hole covers seal unused screw holes to increase overall contact area with the host bone, augment the cup's total mechanical strength, and prevent bone cement extrusion.
    Why is maintaining a uniform joint surface morphology critical across all liners?
    A uniform joint surface morphology ensures that all corresponding liner models preserve identical rotational center positioning, ensuring consistent biomechanical stability across all modular components.

    Leave Your Message