Product Details
Acetabular Mesh & Cage System for Revision Hip Arthroplasty - China Suppliers & Factory Solutions
Special Description
-
Posterosuperior Bone Cement Flange
The posterosuperior bone cement flange minimizes unsupported bone cement.
-
Triple-Flange Reinforcement
3 flanges enhance fixation and offer multiple screw options.
-
Optimized Flange Thickness
Flange thickness of 3mm, balances structural strength and anatomical compatibility.
-
Grooved Acetabular Rim Design
The grooved design on the outer rim of the acetabulum improves adhesion to the acetabular rim, enhancing postoperative outcomes. Boosts prosthesis-bone interface stability.
-
Anatomically Left-Right Differentiation
The left-right differentiation aligns with anatomical characteristics. Ensures better patient-specific fit.
-
Versatile Screw Hole Design
Well-designed screw holes meet diverse clinical needs. Supports flexible surgical strategies.
-
Roughened Surface Texture
The rough surface ensures excellent adhesion of bone cement and promotes osseointegration. Enhances long-term bone-implant integration.
The Acetabular Mesh is designed to reinforce defects in the medial acetabular wall, preventing bone graft migration. The mesh can be shaped, bent, and trimmed during surgery to accommodate individual patient anatomy. Strategically placed slots facilitate precise adjustments. Available in multiple sizes, the Acetabular Mesh provides a customizable solution for acetabular reconstruction.
Special Instrumentation
AOS Ring (Revision)
| Specification | Outer Diameter | Inner Diameter | Cemented Acetabular Cup | |
|---|---|---|---|---|
| 52( L) | 52( R) | 52 | 49 | 42/44/46 |
| 54( L) | 54( R) | 54 | 51 | 46/48 |
| 56( L) | 56( R) | 56 | 53 | 48/50 |
| 58( L) | 58( R) | 58 | 55 | 50/52 |
| 60( L) | 60( R) | 60 | 57 | 54/56 |
| 62( L) | 62( R) | 62 | 59 | 56/58 |
AOS Cage (Revision)
| Specification | Outer Diameter | Inner Diameter | For Cemented Acetabular Cup (Depending on cement thickness) | Acetabular Screw |
|---|---|---|---|---|
| 50( L) | 50 | 47 | 44/46 | 6 |
| 54( L) | 54 | 51 | 48/50 | |
| 58( L) | 58 | 55 | 52/54 | |
| 62( L) | 62 | 59 | 56/58 | |
| 50( R) | 50 | 47 | 44/46 | |
| 54( R) | 54 | 51 | 48/50 | |
| 58( R) | 58 | 55 | 52/54 | |
| 62( R) | 62 | 59 | 56/58 |
Acetabular Mesh (Revision)
| Specification | Acetabular Screw |
|---|---|
| 52 | 4 |
| 54 | |
| 56 | |
| 58 | |
| 60 |
Frequently Asked Questions (FAQ)
The posterosuperior bone cement flange is specifically designed to minimize unsupported bone cement, improving the stability of the reconstruction.
The grooved design on the outer rim of the acetabulum enhances the adhesion of the implant to the acetabular rim, which boosts the stability of the prosthesis-bone interface.
Yes. The Acetabular Mesh can be shaped, bent, and trimmed intraoperatively to fit the patient's specific anatomical requirements. It also features strategically placed slots to facilitate precise adjustments.
The rough surface texture ensures excellent adhesion of bone cement and promotes osseointegration, supporting long-term bone-implant integration.
According to the technical specifications, the Acetabular Mesh (Revision) is designed to utilize 4 acetabular screws for fixation.
Yes, the AOS Cages feature anatomically left-right (L/R) differentiation to align closely with natural anatomical characteristics, ensuring a better patient-specific fit.