Leave Your Message
AUSK Cementless Unicompartmental Knee System

AUSK Unicompartmental Knee System

Product Details

AUSK Cementless Unicompartmental Knee System

China's First and Only Cementless Unicompartmental Tibial Tray, Hybrid Unicompartmental Knee System, and Cementless Unicompartmental Knee System

● Reduced Radiolucency
Significantly lower incidence of physiological radiolucent lines compared to cemented unicompartmental systems (17% vs. 75%).

● Time Efficiency
Compared to traditional cemented systems, surgical time is reduced by 9-10 minutes with cementless fixation.

● Enhanced Stability
Precise sizing control of prostheses and instruments ensures initial stability while minimizing the risk of tibial plateau fractures.

● Superior Bone Integration
A high-quality dual-coating design promotes robust bone growth, contributing to long-term fixation and performance.

 

    Special Description

    AUSK Cementless Uni-knee

    Immediate stability

    01.The column reinforcement design, with precise size control, ensures immediate stability.

    02.Test verification shows that after implantation, the femoral condyle prosthesis exhibits high resistance to pull-out, ensuring excellent initialstability.

    AUSK Cementless Uni-knee (1)

    03.The optimized dual-coating process results in a surface roughness Ra value 1.7 times higher than the standard requirement, enhancing immediate stability.

    AUSK Cementless Uni-knee (2)

    04.The keel is widened, and the processing groove is narrowed, with tool height alignment to ensure immediate stability.

    AUSK Cementless Uni-knee (3)

    Prosthesis stress distribution

    10 million cycles of load testing Verifying excellent fatigue resistance

    Through 10 million cycles of fatigue testing on the coating covering the metal substrate and the prosthesis, it has been verified that under the premise of excellent bonding strength between the dual coating and the substrate, the prosthesis can achieve a very high fatigue limit stress.

    AUSK Cementless Uni-knee (3)

    Animal study Histological observation after sample implantation

    02. Excellent bone growth effect

    New bone is visible at the pore opening.

    The material closely conforms to the new bone.

    No fibrous capsule or inflammatory cells are seen at the material/bone interface.

    AUSK Cementless Uni-knee (3)

    Long-term stability

    01. Good conformability

    Optimized product design and precise surgical instrument design.

    Achieving full contact between the dual-coating and bone tissue, providing a better foundation for bone growth.

    Special Instrumentation

    AUSK Femoral Condyle (Cementless)
    AUSK Femoral Condyle (Cementless)
    Material Spec (mm)
    CoCrMo 1# (for Tibial Bearing 1#)
    2# (for Tibial Bearing 2#)
    3# (for Tibial Bearing 3#)
    4# (for Tibial Bearing 4#)
    AUSK Cementless Uni-knee  (2)
    AUSK Tibial Bearing (Mobile)
    Material Spec (mm)
    Germany Highly Crosslinked PE 1# 3mm R/L 3# 3mm R/L
    1# 4mm R/L 3# 4mm R/L
    1# 5mm R/L 3# 5mm R/L
    1# 6mm R/L 3# 6mm R/L
    1# 7mm R/L 3# 7mm R/L
    2# 3mm R/L 4# 3mm R/L
    2# 4mm R/L 4# 4mm R/L
    2# 5mm R/L 4# 5mm R/L
    2# 6mm R/L 4# 6mm R/L
    2# 7mm R/L 4# 7mm R/L
    AUSK Tibial Tray (Cementless)
    AUSK Tibial Tray (Cementless)
    Material Spec (mm)
    CoCrMo 1# L 1# R
    2# L 2# R
    3# L 3# R
    4# L 4# R
    5# L 5# R
    6# L 6# R
    7# L 7# R

    Technology Education

    AUSK Cementless Unicompartmental Knee System
    JUST MED_Product Brochure_AUSK Cementless Uni-knee.pdf

    description2