Product Details
AUSK Fixed-Bearing Unicompartmental Knee System | Quality China Suppliers & Factory Production
Special Description
Angled Femoral Pegs and 3 Points of Tibial Fixation
Angled femoral pegs are designed to enhance femoral fixation by providing resistance to loosening forces during flexion up to 118°.
2 hour-glass pegs and the rotational fin guard against shear and rotational forces
Tibiofemora Interchangeabilitv
Unconstrained desian allows resulting in complete interchangeability between femora and tibial components
Anatomical Design
The anatomical shape is optimal for bone coverage, while the internal and lateral replacement is possible for wider range of indications
Crosslinked UHMWPE Option
Increased wear resistance with cross-linked polyethylene(XLPE)
Optimized Locking Mechanism
Peripheral locking mechanism with anterior and posterior tongue and groove locks, reduce micromotion between the tibialinsert and base
Round-on-Flat Articulation
Round-on-Flat articulation allows +/-8° varus/valgus tilt without edge loading
Special Instrumentation
AUSK® Femoral Condyle (Fixed)
| Material | Spec (mm) | |
|---|---|---|
| CoCrMo | 1# LM/RL | 4# LM/RL |
| 1# RM/LL | 4# RM/LL | |
| 2# LM/RL | 5# LM/RL | |
| 2# RM/LL | 5# RM/LL | |
| 3# LM/RL | 6# LM/RL | |
| 3# RM/LL | 6# RM/LL | |
AUSK® Tibial Bearing (Fixed)
| Material | Spec (mm) | |
|---|---|---|
| Germany Highly Crosslinked PE | 1# 9mm,10mm,11mm, 12mm,13mm,14mm |
4# 9mm,10mm,11mm, 12mm,13mm,14mm |
| 2# 9mm,10mm,11mm, 12mm,13mm,14mm |
5# 9mm,10mm,11mm, 12mm,13mm,14mm |
|
| 3# 9mm,10mm,11mm, 12mm,13mm,14mm |
6# 9mm,10mm,11mm, 12mm,13mm,14mm |
|
AUSK® Tibial Tray (Fixed)
| Material | Spec (mm) | |
|---|---|---|
| CoCrMo | 1# LM/RL | 4# LM/RL |
| 1# RM/LL | 4# RM/LL | |
| 2# LM/RL | 5# LM/RL | |
| 2# RM/LL | 5# RM/LL | |
| 3# LM/RL | 6# LM/RL | |
| 3# RM/LL | 6# RM/LL | |
Video
Frequently Asked Questions
Q:
What is the benefit of the angled femoral pegs in the AUSK® System?
A: Angled femoral pegs are designed to enhance femoral fixation by providing strong resistance to loosening forces during flexion up to 118°.
Q:
Does the AUSK® system allow component interchangeability?
A: Yes, the unconstrained design of the system allows for complete interchangeability between the femoral and tibial components.
Q:
How does the anatomical design improve surgical outcomes?
A: The anatomical shape is optimized for optimal bone coverage. Additionally, internal and lateral replacement is possible, accommodating a wider range of clinical indications.
Q:
What options are available for the Tibial Bearing material?
A: The system offers a Crosslinked UHMWPE option (Germany Highly Crosslinked PE) which provides increased wear resistance.
Q:
How does the optimized locking mechanism reduce micromotion?
A: It utilizes a peripheral locking mechanism featuring anterior and posterior tongue and groove locks to minimize micromotion between the tibial insert and base.
Q:
What range of tilt does the Round-on-Flat articulation allow?
A: The Round-on-Flat articulation permits a +/-8° varus/valgus tilt without causing edge loading.