Product Details
China Suppliers DELTA CLASSIC Rectangular Femoral Stem - Advanced Titanium Design for Enhanced Stability from Factory
Special Description
- The reduced lateral shoulder eases stem insertion
- Rectangular cross section design resists axial/torsional stresses for initial stability
- The proximal steps designed to convert hoop stresses to compression loads to avoid intra-operative fracture, and provide consistent implant seating height and initial stability
- Distal vertical/horizontal grooves provide rotational and axial stability
- Optimal offset aiming to restore hip biomechanics Ti6Al4V material and Ti+HA double layered coating (225 micron Ti coating plus 70 micron HA coating) ensure long-term bone ingrowth
-
Proximal stem stepped designOptimizes stress distribution by converting circumferential shear stress to axial compressive stress, enhancing axial stability
-
Distal stem vertical / horizontal groove designProvide rotational and axial stability
-
Side shoulder cutting designEasy implantation process
-
Base material:TC4, Ti + HA double coating
-
Ti coating thickness: 225 µm
-
HA coating thickness: 70 µm
- Excellent long-term bone ingrowth
Special Instrumentation
DELTA™ Classic Stem, Ti+HA (Vacuum Plasma Sprayed)
| Specification | Stem length (mm) | Offset | Neck Angle | Material |
|---|---|---|---|---|
| 6# | 115 | 36 | 132° | Ti6Al4V |
| 9# | 130 | 38 | ||
| 10# | 140 | 40 | ||
| 11# | 145 | 40 | ||
| 12# | 150 | 42 | ||
| 13# | 155 | 42 | ||
| 14# | 160 | 44 | ||
| 15# | 165 | 44 | ||
| 16# | 170 | 46 |
Technology Education
FAQ
-
Osteoarthritis, Femoral head necrosis, Femoral neck fracture, Rheumatoid arthritis, Ankylosing spondylitis, Dorr types A, B, and C medullary canal morphology.
It is also designed for standard primary hip replacement.
-
Yes, the implant is made from non-magnetic materials like titanium, titanium alloys, and cobalt-chromium-molybdenum alloys, ensuring MRI safety. JUST MEDICAL's products meet these standards, but always inform your radiologist before scanning.
-
Designed exclusively for cementless fixation.
Promotes excellent long-term bone growth for stable and durable fixation.
Eliminates the need for bone cement.
-
The implant features a Ti+HA double-layered coating on a TC4 base. The titanium (Ti) coating thickness is 225 µm, and the hydroxyapatite (HA) coating thickness is 70 µm, which facilitates excellent long-term bone ingrowth.
-
The rectangular cross-section design resists axial and torsional stresses. Additionally, the distal vertical and horizontal grooves provide rotational and axial stability, while the proximal steps convert hoop stresses to compression loads.
-
The stem is available in specifications from 6# to 16#, with stem lengths ranging from 115mm to 170mm, offsets from 36mm to 46mm, and a standard neck angle of 132°.