Product Details
HARMONY Tapered Femoral Stem - Premium China Suppliers and Factory for Advanced Prosthetic Solutions
Special Description

Proximal Step-Design
- Increases coating surface area to block debris, reducing postoperative loosening
- Stair-step and secondary compressive trabecular alignment
- Effectively prevents femoral stem subsidence
Wolff's Law Alignment
- Pattern of load transmitting follows Wolff's Law
Three Coating Options
- Option 1: Ti (Air Plasma Sprayed)
- Option 2: Ti (Vacuum Plasma Sprayed)
- Option 3: Ti+HA (Vacuum Plasma Sprayed)
- Porosity: 70%
- Ti coating thickness: 325 um, HA coating thickness: 50 um
- Increase friction with cortical bone for immediate stability
- Good biocompatibility effectively promotes bone growth
Optimized Head-Neck Ratio
- Significantly increases range of motion
- 28mm head → increase 12°
- 32mm head → increase 20°
High Offset Design
- Proportional neck length and offset design effectively increase range of motion
Special Instrumentation
| Specification | Stem length (mm) | Offset | Neck Angle | Material |
|---|---|---|---|---|
| 09# | 135 | 38 | 130° | Ti6Al4V |
| 10# | 140 | 38 | ||
| 11# | 145 | 40 | ||
| 12# | 150 | 40 | ||
| 13# | 155 | 44 | ||
| 14# | 160 | 44 | ||
| 15# | 165 | 46 | ||
| 16# | 170 | 46 |
| Specification | Stem length (mm) | Offset | Neck Angle | Material |
|---|---|---|---|---|
| 09# | 134 | 38 | 130° | Ti6Al4V |
| 10# | 140 | 38 | ||
| 11# | 145 | 40 | ||
| 12# | 151 | 40 | ||
| 13# | 156 | 44 | ||
| 14# | 162 | 44 | ||
| 15# | 168 | 46 | ||
| 16# | 173 | 46 | ||
| 17# | 178 | 48 |
| Specification | Stem length (mm) | Offset | Neck Angle | Material |
|---|---|---|---|---|
| 09# | 134 | 38 | 130° | Ti6Al4V |
| 10# | 140 | 38 | ||
| 11# | 145 | 40 | ||
| 12# | 151 | 40 | ||
| 13# | 156 | 44 | ||
| 14# | 162 | 44 | ||
| 15# | 168 | 46 | ||
| 16# | 173 | 46 | ||
| 17# | 178 | 48 |
Video Demonstration
FAQ
1. Which patients is this hip implant suitable for?
2. Can patients undergo MRI scans after implantation?
Yes, the implant is made from non-magnetic materials like titanium, titanium alloys, and cobalt-chromium-molybdenum alloys, ensuring MRI safety. JUST MEDICAL's products meet these standards, but always inform your radiologist before scanning.
3. Does this product support cemented or cementless fixation?
4. What is the benefit of the Proximal Step-Design?
The proximal step-design increases the coating surface area to block wear debris, reducing the risk of postoperative loosening and effectively preventing femoral stem subsidence.
5. How does the optimized head-neck ratio impact the range of motion?
It significantly increases the range of motion. Specifically, using a 28mm head increases the angle by 12°, while a 32mm head provides an increase of 20°.
6. What coating options are available for the HARMONY™ Stem?
There are three options: Ti (Air Plasma Sprayed), Ti (Vacuum Plasma Sprayed), and Ti+HA (Vacuum Plasma Sprayed). The Ti coating thickness is 325 um, and the HA coating thickness is 50 um, with a porosity of 70% to promote bone growth and ensure immediate stability.