High Flexion Total Knee System SKII PS/PS+ - China Suppliers & Factory for Enhanced Stability and Osteolysis Risk Reduction

● Intraoperative Flexibility
Choose between PS and PS+ tibial bearings to enhance stability during surgery:

,

PS: With no varus/valgus constraint, this option allows for up to 15° internal/external rotation, providing greater flexibility for surgeons.

,

PS+: This option restricts varus/valgus deviation to 2° and limits internal/external rotation to ±2°, offering added control for surgical procedures.

,

● Enhanced Stability
The anterior dovetail design of our tibial bearing significantly reduces micromotion between the bearing and tibial tray, ensuring superior stability compared to competitors.

,

● Osteolysis Risk Reduction
Featuring a tapped bind hole on the tibial tray, our product minimizes the risk of osteolysis due to wear, making it an ideal choice for medical professionals.

,

As a leading factory and supplier in China, we are committed to providing high-quality products that meet the needs of the healthcare industry.

    Special Description

    SKII PS+-1-2
    2 Options of Tibial Bearings
    Standard and PLUS
    • PS: No varus/valgus constraint
    • PS: 15 degrees internal/external rotation
    • PS+: 2 degrees varus/valgus constraint
    • PS+: +/-2 degrees internal/external rotation
    • Using in a primary situation when more stability and initial constraint is desired to resist rotation and varus/valgus lift-off
    SKII PS+-1-3
    Stem Extensions

    For optimal stress distribution

    Same Platform Design

    Meets requirements of both primary and complex primary TKA

    Augment Options

    Multiple specifications tibial augment for varying degrees or shapes of the tibial bone defect

    Product Features-Seamless System, Deal with Possible Bone Defects

    SKII PS+-2-2
    Normal Primary TKA
    SKII PS+-2-3
    Complex Primary TKA

    Tibial defect is treated with tibial augment stem is required to protect the defect.

    SKII PS+-2-4
    Severe Tibial Defect

    Large central tibial defect is treated with tibial cone stem is used to strengthen prosthesis fixation.

    Special Instrumentation

    SKII™ Femoral Condyle (PS)

    Material Spec (mm)
    CoCrMo 1# L 1# R
    2# L 2# R
    3# L 3# R
    4# L 4# R
    5# L 5# R
    6# L 6# R
    7# L 7# R
    8# L 8# R
    9# L 9# R
    SKII PSPS+ High Flexion Total Knee System (1)

    SKII™ Tibial Bearing (PS)

    Material Spec (mm) A/P (mm) M/L (mm)
    Germany UHMWPE 1# 10mm,12mm,14mm,16mm 38 59
    2# 10mm,12mm,14mm,16mm
    (for Tibial Tray 2#/3#)
    41/43 63/67
    4# 10mm,12mm,14mm,16mm
    (for Tibial Tray 4#/5#)
    46/48 71/75
    6# 10mm,12mm,14mm,16mm
    (for Tibial Tray 6#/7#)
    51/53 79/83
    SKII PSPS+ High Flexion Total Knee System (2)

    SKII™ Tibial Bearing (PS PLUS Constrained)

    Material Spec (mm) A/P (mm) M/L (mm)
    Germany UHMWPE 1# 10mm,12mm,14mm,16mm 38 59
    2# 10mm,12mm,14mm,16mm
    (for Tibial Tray 2#/3#)
    41/43 63/67
    4# 10mm,12mm,14mm,16mm
    (for Tibial Tray 4#/5#)
    46/48 71/75
    6# 10mm,12mm,14mm,16mm
    (for Tibial Tray 6#/7#)
    51/53 79/83
    SKII PSPS+ High Flexion Total Knee System (3)

    SKII™ Tibial Tray

    Material Spec (mm) A/P (mm) M/L (mm)
    CoCrMo 1# 38 59
    2# 41 63
    3# 43 67
    4# 46 71
    5# 48 75
    6# 51 79
    7# 53 83
    SKII PSPS+ High Flexion Total Knee System (4)

    Video Demonstration

    Technology Education

    Surgical Technique Manual Thumbnail
    JUST MED_Surgical Technique Manual_SKII PS High Flexion Total Knee System.pdf
    download icon Download PDF

    Frequently Asked Questions (FAQ)

    What are the options for the SKII™ Tibial Bearings?

    The SKII™ system offers two tibial bearing options: Standard (PS) and PLUS (PS+). The Standard PS bearing features no varus/valgus constraint with 15 degrees of internal/external rotation, while the PS+ Constrained bearing provides 2 degrees of varus/valgus constraint and +/-2 degrees of internal/external rotation.

    When is the SKII™ PS+ Constrained Tibial Bearing recommended?

    The PS+ bearing is recommended for primary joint situations when higher stability and initial constraints are desired to resist rotation and varus/valgus lift-off.

    What materials are used in the construction of the SKII™ Total Knee System?

    The SKII™ Femoral Condyle and Tibial Tray are constructed from durable Cobalt-Chromium-Molybdenum (CoCrMo) alloy. The Tibial Bearings are made from high-quality Germany Ultra-High-Molecular-Weight Polyethylene (UHMWPE).

    How does the SKII™ system accommodate different types of tibial bone defects?

    The system features a Same Platform Design that accommodates normal primary TKA, complex primary TKA (using tibial augments and stems to protect defects), and severe tibial defects (utilizing tibial cones and stems to reinforce fixation).

    What sizing specifications are available for the SKII™ Tibial Tray?

    The SKII™ Tibial Tray is available in seven different sizes (1# to 7#), with A/P dimensions ranging from 38mm to 53mm and M/L dimensions ranging from 59mm to 83mm to ensure a precise anatomical fit.