Leave Your Message
High-Quality RSK PS High Flexion Hybrid Revision Knee System - Direct from China Suppliers and Factory
Hot Products

Product Details

High-Quality RSK PS High Flexion Hybrid Revision Knee System - Direct from China Suppliers and Factory

,

●  Optimized Femoral Design for Enhanced Performance

,

Available in 8 Sizes with Built-In 5° Valgus Angle
This design guarantees optimal bone coverage and adaptability, providing superior fit for patients.

,

Enlarged Lateral Posterior Condyle & Ultra-Mirror Polishing
These features increase joint contact, reduce wear, and minimize debris, ensuring long-term durability.

,

●  Effective Defect Management Solutions

,

Extension Rod and Block Connectivity
Our design simplifies the effective management of femoral bone defects during surgery, allowing for precision and reliability.

,

●  Efficient Tibial Bearing Insertion Technology

,

High Flexion Support
Compatible with all femoral condyle models, supporting flexion up to 145° for enhanced mobility.

,

Easy Posterior Insertion
This feature facilitates quick and accurate installation with the tibial tray, while a widened and heightened post with a hook reduces the risk of dislocation.

,

●  Innovative Tibial Tray Design

,

Advanced Locking Mechanism & Polished Surface
These characteristics minimize backside micromotion and wear, accommodating augments and stem extensions for complex surgical cases.

,

1:1 Tibiofemoral Surface Contact & Narrowed Keel
This design maximizes load distribution while conserving bone stock, making our products a preferred choice among China’s leading suppliers and manufacturers.

,

    Special Description

    RSK (5)

    5° Valgus Stem Alignment

    • Anatomical stem valgus angle for natural femoral fit
    • Accommodates offset stems to optimize component positioning
    SKII RPS High Flexion Total Knee System

    Bone-Preserving Intercondylar Design

    • ≤22mm narrow intercondylar box
    • Maximizes bone conservation in distal femur
    SKII RPS High Flexion Total Knee System (2)

    Dual Constraint System

    • 0.5° controlled internal/external rotation
    • 1° varus/valgus constraint tolerance
    • Non-hinged constrained bearing maintains stability in ligament-deficient clinical scenarios
    RSK (1)

    Double Locking Mechanism

    • NO.1 Locking Screw
    • NO.2 Advanced locking mechanism reduces backside micromotion to the lowest level
    RSK (2)

    Tibial Augment

    • Reestablish joint line alignment
    • Reduce extension gap
    • VS wedge design minimizes shear forces, improves joint stability
    RSK (3)

    Tibial Cone

    • Stepped geometry for compressive bone loading
    • Preserves native joint line position
    • Eliminates bone graft requirements
    RSK (2)

    Special Instrumentation

    RSK® PS High Flexion Hybrid Revision Knee System (1)
    RSK™ Femoral Condyle (PS)
    Material Spec (mm)
    CoCrMo 1# L 1# R
    2# L 2# R
    3# L 3# R
    4# L 4# R
    5# L 5# R
    6# L 6# R
    7# L 7# R
    8# L 8# R
    RSK® PS High Flexion Hybrid Revision Knee System (2)
    RSK™ Tibial Bearing (PS)
    Material Spec (mm) A/P (mm) M/L (mm)
    Germany UHMWPE 1# 10mm, 12mm, 14mm, 16mm, 18mm, 20mm 38 59
    2# 10mm, 12mm, 14mm, 16mm, 18mm, 20mm
    (for Tibial Tray 2#/3#)
    41/43 63/67
    4# 10mm, 12mm, 14mm, 16mm, 18mm, 20mm
    (for Tibial Tray 4#/5#)
    46/48 71/75
    6# 10mm, 12mm, 14mm, 16mm, 18mm, 20mm
    (for Tibial Tray 6#/7#)
    51/53 79/83
    RSK® PS High Flexion Hybrid Revision Knee System (3)
    RSK™ Tibial Tray
    Material Spec (mm) A/P (mm) M/L (mm)
    CoCrMo 1# 38 59
    2# 41 63
    3# 43 67
    4# 46 71
    5# 48 75
    6# 51 79
    7# 53 83

    Video

    Frequently Asked Questions

    What are the advantages of the 5° Valgus Stem Alignment?
    The 5° Valgus Stem Alignment features an anatomical stem valgus angle that ensures a natural femoral fit. Additionally, it accommodates offset stems to optimize component positioning during knee reconstruction.
    How does the RSK system maximize bone preservation?
    The system utilizes a Bone-Preserving Intercondylar Design featuring a narrow intercondylar box of ≤22mm, which significantly maximizes bone conservation in the distal femur.
    What features does the Dual Constraint System offer for joint stability?
    The Dual Constraint System provides 0.5° controlled internal/external rotation and 1° varus/valgus constraint tolerance. Its non-hinged constrained bearing is specifically designed to maintain stability in ligament-deficient clinical scenarios.
    How does the Double Locking Mechanism function?
    It features a dual-stabilizing design: NO.1 is a secure Locking Screw, and NO.2 is an advanced locking mechanism that reduces backside micromotion to the lowest possible level.
    What is the purpose of the Tibial Augment and Tibial Cone?
    The Tibial Augment helps reestablish joint line alignment, reduces extension gaps, and features a VS wedge design to minimize shear forces. The Tibial Cone uses a stepped geometry for compressive bone loading, preserving native joint line position and eliminating bone graft requirements.
    What materials are used in the RSK system components?
    The RSK™ Femoral Condyle and Tibial Tray are manufactured from CoCrMo (Cobalt-Chromium-Molybdenum) alloy, while the RSK™ Tibial Bearing is made of high-quality German UHMWPE (Ultra-High-Molecular-Weight Polyethylene).