Leave Your Message
RSK PS High Flexion Hybrid Revision Knee System - China Suppliers Factory for Optimized Femoral Design and Tibial Tray Solutions
Hot Products

Product Details

RSK PS High Flexion Hybrid Revision Knee System - China Suppliers Factory for Optimized Femoral Design and Tibial Tray Solutions

,

●  Optimized Femoral Design

,

8 Sizes with Built-In 5° Valgus Angle
This design ensures optimal bone coverage and adaptability, making it a preferred choice among top China suppliers in the orthopedic industry.

,

Enlarged Lateral Posterior Condyle & Ultra-Mirror Polishing
Enhances joint contact, reduces wear, and minimizes debris, setting a high standard for products manufactured in our factory.

,

●  Defect Management

,

Extension Rod and Block Connectivity
This feature facilitates effective management of femoral bone defects during surgery, showcasing our commitment to quality as leading suppliers in China.

,

●  Efficient Tibial Bearing Insertion

,

High Flexion Support
Compatible with all femoral condyle models, our product supports flexion up to 145°, ideal for diverse surgical needs.

,

Easy Posterior Insertion
The design ensures quick and accurate installation with the tibial tray, featuring a widened and heightened post with a hook to reduce dislocation risk, affirming our status as a reliable factory for orthopedic solutions.

,

●  Tibial Tray Design

,

Advanced Locking Mechanism & Polished Surface
Minimizes backside micromotion and wear while accepting augments and stem extensions for complex cases, showcasing our innovation as top suppliers from China.

,

1:1 Tibiofemoral Surface Contact & Narrowed Keel
Maximizes load distribution and conserves bone stock, reflecting the high-quality manufacturing standards of our factory.

,

    Special Description

    5° Valgus Stem Alignment

    5° Valgus Stem Alignment

    • Anatomical stem valgus angle for natural femoral fit
    • Accommodates offset stems to optimize component positioning
    Bone-Preserving Intercondylar Design

    Bone-Preserving Intercondylar Design

    • ≤22mm narrow intercondylar box
    • Maximizes bone conservation in distal femur
    Dual Constraint System

    Dual Constraint System

    • 0.5° controlled internal/external rotation
    • 1° varus/valgus constraint tolerance
    • Non-hinged constrained bearing maintains stability in ligament-deficient clinical scenarios
    Double Locking Mechanism

    Double Locking Mechanism

    • NO.1Locking Screw
    • NO.2Advanced locking mechanism reduces backside micromotion to the lowest level
    Tibial Augment

    Tibial Augment

    • Reestablish joint line alignment
    • Reduce extension gap
    • VS wedge design minimizes shear forces, improves joint stability
    Tibial Cone

    Tibial Cone

    • Stepped geometry for compressive bone loading
    • Preserves native joint line position
    • Eliminates bone graft requirements
    RSK Alignment System

    Special Instrumentation

    RSK Femoral Condyle (PS)

    RSK™ Femoral Condyle (PS)

    Material Spec (mm)
    CoCrMo 1# L 1# R
    2# L 2# R
    3# L 3# R
    4# L 4# R
    5# L 5# R
    6# L 6# R
    7# L 7# R
    8# L 8# R
    RSK Tibial Bearing (PS)

    RSK™ Tibial Bearing (PS)

    Material Spec (mm) A/P (mm) M/L (mm)
    Germany UHMWPE 1# 10mm, 12mm, 14mm, 16mm, 18mm, 20mm 38 59
    2# 10mm, 12mm, 14mm, 16mm, 18mm, 20mm
    (for Tibial Tray 2#/3#)
    41/43 63/67
    4# 10mm, 12mm, 14mm, 16mm, 18mm, 20mm
    (for Tibial Tray 4#/5#)
    46/48 71/75
    6# 10mm, 12mm, 14mm, 16mm, 18mm, 20mm
    (for Tibial Tray 6#/7#)
    51/53 79/83
    RSK Tibial Tray

    RSK™ Tibial Tray

    Material Spec (mm) A/P (mm) M/L (mm)
    CoCrMo 1# 38 59
    2# 41 63
    3# 43 67
    4# 46 71
    5# 48 75
    6# 51 79
    7# 53 83

    Video Demonstration

    Frequently Asked Questions (FAQ)

    Q: What are the benefits of the 5° Valgus Stem Alignment in the RSK system?
    The 5° Valgus Stem Alignment features an anatomical stem valgus angle that ensures a natural femoral fit. Additionally, it accommodates offset stems to optimize component positioning during surgery.
    Q: How does the RSK system promote bone preservation?
    It features a bone-preserving intercondylar design with a narrow intercondylar box of ≤22mm, which maximizes bone conservation in the distal femur.
    Q: What makes the Dual Constraint System stable in ligament-deficient scenarios?
    The system provides a 0.5° controlled internal/external rotation and a 1° varus/valgus constraint tolerance. Its non-hinged constrained bearing maintains exceptional stability even in ligament-deficient clinical scenarios.
    Q: How does the Double Locking Mechanism prevent micromotion?
    The system utilizes a dual configuration featuring a Locking Screw (NO.1) and an advanced locking mechanism (NO.2) that reduces backside micromotion to the lowest possible level.
    Q: What functions do the Tibial Augment and Tibial Cone perform?
    The Tibial Augment reestablishes joint line alignment, reduces extension gaps, and features a VS wedge design to minimize shear forces. The Tibial Cone uses a stepped geometry for compressive bone loading, preserving the native joint line and eliminating the need for bone grafts.
    Q: What materials are used in the RSK instrumentation?
    The RSK™ Femoral Condyle and Tibial Tray are constructed from highly durable CoCrMo (Cobalt-Chromium-Molybdenum) alloy. The RSK™ Tibial Bearing is made from premium Germany UHMWPE (Ultra-High-Molecular-Weight Polyethylene).