●  Optimized Femoral Design

,

8 Sizes with Built-In 5° Valgus Angle
Designed for optimal bone coverage and adaptability, catering to diverse patient needs.

,

Enlarged Lateral Posterior Condyle & Ultra-Mirror Polishing
Enhances joint contact, minimizes wear, and reduces debris, ensuring longevity and functionality.

,

●  Defect Management

,

Extension Rod and Block Connectivity
Enables effective management of femoral bone defects during surgical procedures, enhancing surgical success rates.

,

●  Efficient Tibial Bearing Insertion

,

High Flexion Support
Compatible with all femoral condyle models, supporting flexion angles up to 145° for improved mobility.

,

Easy Posterior Insertion
Facilitates rapid and accurate installation with the tibial tray, featuring a widened, heightened post that reduces dislocation risk.

,

●  Tibial Tray Design

,

Advanced Locking Mechanism & Polished Surface
Reduces backside micromotion and wear while accommodating augments and stem extensions for complex cases, making it a choice product for China suppliers and factories.

,

1:1 Tibiofemoral Surface Contact & Narrowed Keel
Maximizes load distribution and conserves bone stock, enhancing overall joint stability and performance.

,

    Special Description

    RSK (5)

    5° Valgus Stem Alignment

    • Anatomical stem valgus angle for natural femoral fit
    • Accommodates offset stems to optimize component positioning
    SKII RPS High Flexion Total Knee System

    Bone-Preserving Intercondylar Design

    • ≤22mm narrow intercondylar box
    • Maximizes bone conservation in distal femur
    SKII RPS High Flexion Total Knee System (2)

    Dual Constraint System

    • 0.5° controlled internal/external rotation
    • 1° varus/valgus constraint tolerance
    • Non-hinged constrained bearing maintains stability in ligament-deficient clinical scenarios
    RSK (1)

    Double Locking Mechanism

    • NO.1 Locking Screw
    • NO.2 Advanced locking mechanism reduces backside micromotion to the lowest level
    RSK (2)

    Tibial Augment

    • Reestablish joint line alignment
    • Reduce extension gap
    • VS wedge design minimizes shear forces, improves joint stability
    RSK (3)

    Tibial Cone

    • Stepped geometry for compressive bone loading
    • Preserves native joint line position
    • Eliminates bone graft requirements
    RSK (2)

    Special Instrumentation

    RSK® PS High Flexion Hybrid Revision Knee System (1)

    RSK™ Femoral Condyle (PS)

    Material Spec (mm)
    CoCrMo 1# L 1# R
    2# L 2# R
    3# L 3# R
    4# L 4# R
    5# L 5# R
    6# L 6# R
    7# L 7# R
    8# L 8# R
    RSK® PS High Flexion Hybrid Revision Knee System (2)

    RSK™ Tibial Bearing (PS)

    Material Spec (mm) A/P (mm) M/L (mm)
    Germany UHMWPE 1# 10mm, 12mm, 14mm, 16mm, 18mm, 20mm 38 59
    2# 10mm, 12mm, 14mm, 16mm, 18mm, 20mm
    (for Tibial Tray 2#/3#)
    41/43 63/67
    4# 10mm, 12mm, 14mm, 16mm, 18mm, 20mm
    (for Tibial Tray 4#/5#)
    46/48 71/75
    6# 10mm, 12mm, 14mm, 16mm, 18mm, 20mm
    (for Tibial Tray 6#/7#)
    51/53 79/83
    RSK® PS High Flexion Hybrid Revision Knee System (3)

    RSK™ Tibial Tray

    Material Spec (mm) A/P (mm) M/L (mm)
    CoCrMo 1# 38 59
    2# 41 63
    3# 43 67
    4# 46 71
    5# 48 75
    6# 51 79
    7# 53 83

    Video

    Frequently Asked Questions

    What are the benefits of the 5° Valgus Stem Alignment?

    The 5° Valgus Stem Alignment features an anatomical stem valgus angle for a natural femoral fit and accommodates offset stems to optimize component positioning.

    How does the intercondylar design preserve bone?

    It utilizes a bone-preserving intercondylar design with a narrow intercondylar box of ≤22mm, which maximizes bone conservation in the distal femur.

    What stability features does the Dual Constraint System offer?

    The system provides 0.5° controlled internal/external rotation, 1° varus/valgus constraint tolerance, and features a non-hinged constrained bearing to maintain stability in ligament-deficient clinical scenarios.

    How does the Double Locking Mechanism work to reduce micromotion?

    It utilizes a NO.1 Locking Screw along with a NO.2 Advanced locking mechanism that reduces backside micromotion to the lowest level.

    What are the functions of the Tibial Augment and Tibial Cone?

    The Tibial Augment reestablishes joint line alignment, reduces extension gap, and uses a VS wedge design to minimize shear forces. The Tibial Cone features a stepped geometry for compressive bone loading, preserves native joint line position, and eliminates bone graft requirements.

    What materials are used for the revision knee system instrumentation?

    The RSK™ Femoral Condyle (PS) and Tibial Tray are made of CoCrMo, while the RSK™ Tibial Bearing (PS) is made of Germany UHMWPE.