Product Details
SKII CR High Flexion Total Knee System - China Suppliers & Factory for Enhanced Mobility and Proprioception
Designed for high flexion activity
◈
2 options of tibial bearings: CR and AS
◈
Mirror-polished surface finish to reduce bearing wear during motion
◈
3 degrees posterior slope
◈
15 degrees internal/external rotation
◈
Prominent 10 mm anterior lip
◈
5 mm posterior lip
◈
6 degrees internal/external rotation
✔Anterior Constraint
✔Posterior Lip & Central projection
✔Locking Tab to Secure Insert
✔Interference Fit Between insert and Tibial Base
Absorb anterior/posterior, medial/lateral, and rotational forces
Product Features - Anti-Dislocation Design
Ultra-congruent deep-dish design insert with a prominent anterior lip, acts as a posterior-stabilizing device by allowing the femoral component to move within the deep-dish configuration. It provides patients with more natural motion and the potential for greater implant longevity without requiring a PS post.

SKII™ Femoral Condyle (CR)
| Material | Spec (mm) | |
|---|---|---|
| CoCrMo | 1# L | 1# R |
| 2# L | 2# R | |
| 3# L | 3# R | |
| 4# L | 4# R | |
| 5# L | 5# R | |
| 6# L | 6# R | |
| 7# L | 7# R | |
| 8# L | 8# R | |
| 9# L | 9# R | |

SKII™ Tibial Bearing (CR)
| Material | Spec (mm) | A/P (mm) | M/L (mm) |
|---|---|---|---|
| Germany UHMWPE | 1# 10/12/14/16mm | 38 | 59 |
| 2# 10/12/14/16mm (for 2#/3#) | 41/43 | 63/67 | |
| 4# 10/12/14/16mm (for 4#/5#) | 46/48 | 71/75 | |
| 6# 10/12/14/16mm (for 6#/7#) | 51/53 | 79/83 |

SKII™ Tibial Bearing (Anterior Stabilized)
| Material | Spec (mm) | A/P (mm) | M/L (mm) |
|---|---|---|---|
| Germany UHMWPE | 1# 10/12/14/16mm | 38 | 59 |
| 2# 10/12/14/16mm | 41 | 63 | |
| 3# 10/12/14/16mm | 43 | 67 | |
| 4# 10/12/14/16mm | 46 | 71 | |
| 5# 10/12/14/16mm | 48 | 75 | |
| 6# 10/12/14/16mm | 51 | 79 | |
| 7# 10/12/14/16mm | 53 | 83 |

SKII™ Tibial Tray
| Material | Spec (mm) | A/P (mm) | M/L (mm) |
|---|---|---|---|
| CoCrMo | 1# | 38 | 59 |
| 2# | 41 | 63 | |
| 3# | 43 | 67 | |
| 4# | 46 | 71 | |
| 5# | 48 | 75 | |
| 6# | 51 | 79 | |
| 7# | 53 | 83 |
Frequently Asked Questions
Q: What are the primary benefits of the SKII™ CR High Flexion System?
A: It is specifically designed for high flexion activities, offering a mirror-polished surface to reduce wear and providing up to 15 degrees of internal/external rotation for natural motion.
Q: What types of tibial bearings are compatible with this system?
A: The system supports two main options of tibial bearings: Cruciate Retaining (CR) and Anterior Stabilized (AS).
Q: How does the anti-dislocation design provide stability?
A: It utilizes an ultra-congruent deep-dish design with a prominent 10mm anterior lip, which acts as a posterior-stabilizing device without the need for a PS post.
Q: What materials are used in the SKII™ components?
A: The femoral condyles and tibial trays are made from CoCrMo (Cobalt-Chromium-Molybdenum), while the tibial bearings are manufactured from high-quality Germany UHMWPE.
Q: Does the system account for posterior slope?
A: Yes, the design includes a 3-degree posterior slope to accommodate natural knee anatomy and movement.
Q: How is the insert secured to the tibial base?
A: The system features a locking tab and an interference fit between the insert and the tibial base to ensure maximum security and force absorption.