● Intraoperative Flexibility
Choose between PS or PS+ tibial bearings to tailor stability to your needs. As a top supplier in China, our products ensure optimal performance during surgery.

,

PS: This option features no varus/valgus constraint, allowing up to 15° of internal/external rotation for enhanced adaptability.

,

PS+: Offers restricted 2° varus/valgus deviation and ±2° internal/external rotation for improved stability during movements, making it a preferred choice among leading manufacturers.

,

● Enhanced Stability
Our tibial bearing includes an innovative anterior dovetail design, effectively minimizing micromotion between the bearing and the tibial tray, surpassing competing brands available in the market.

,

● Osteolysis Risk Reduction
Featuring a tapped bind hole on the tibial tray, our design significantly mitigates the risk of osteolysis caused by material wear, establishing our factory as a reliable source for orthopedic solutions.

    Special Description

    SKII PS+-1-2

    2 Options of Tibial Bearings

    Standard and PLUS

    • PS: No varus/valgus constraint
    • PS: 15 degrees internal/external rotation
    • PS+: 2 degrees varus/valgus constraint
    • PS+: +/-2 degrees internal/external rotation

    Using in a primary situation when more stability and initial constraint is desired to resist rotation and varus/valgus lift-off.

    SKII PS+-1-3

    Stem Extensions

    For optimal stress distribution

    Same Platform Design

    Meets requirements of both primary and complex primary TKA

    Augment Options

    Multiple specifications tibial augment for varying degrees or shapes of the tibial bone defect

    Product Features - Seamless System, Deal with Possible Bone Defects
    SKII PS+-2-2

    Normal Primary TKA

    SKII PS+-2-3

    Complex Primary TKA

    Tibial defect is treated with tibial augment stem is required to protect the defect.

    SKII PS+-2-4

    Large central tibial defect is treated with tibial cone stem is used to strengthen prosthesis fixation.

    Special Instrumentation

    SKII™ Femoral Condyle (PS)

    Material Spec (mm)
    CoCrMo 1# L 1# R
    2# L 2# R
    3# L 3# R
    4# L 4# R
    5# L 5# R
    6# L 6# R
    7# L 7# R
    8# L 8# R
    9# L 9# R
    SKII Femoral Condyle

    SKII™ Tibial Bearing (PS)

    Material Spec (mm) A/P (mm) M/L (mm)
    Germany UHMWPE 1# 10mm,12mm,14mm,16mm 38 59
    2# 10mm,12mm,14mm,16mm
    (for Tibial Tray 2#/3#)
    41/43 63/67
    4# 10mm,12mm,14mm,16mm
    (for Tibial Tray 4#/5#)
    46/48 71/75
    6# 10mm,12mm,14mm,16mm
    (for Tibial Tray 6#/7#)
    51/53 79/83
    SKII Tibial Bearing

    SKII™ Tibial Bearing (PS PLUS Constrained)

    Material Spec (mm) A/P (mm) M/L (mm)
    Germany UHMWPE 1# 10mm,12mm,14mm,16mm 38 59
    2# 10mm,12mm,14mm,16mm
    (for Tibial Tray 2#/3#)
    41/43 63/67
    4# 10mm,12mm,14mm,16mm
    (for Tibial Tray 4#/5#)
    46/48 71/75
    6# 10mm,12mm,14mm,16mm
    (for Tibial Tray 6#/7#)
    51/53 79/83
    SKII Tibial Bearing PS PLUS

    SKII™ Tibial Tray

    Material Spec (mm) A/P (mm) M/L (mm)
    CoCrMo 1# 38 59
    2# 41 63
    3# 43 67
    4# 46 71
    5# 48 75
    6# 51 79
    7# 53 83
    SKII Tibial Tray

    Video

    Technology Education

    Surgical Technique Manual Cover
    JUST MED_Surgical Technique Manual_SKII PS High Flexion Total Knee System.pdf

    Frequently Asked Questions (FAQ)

    What is the difference between the PS and PS+ Tibial Bearings?
    The PS (Standard) bearing offers no varus/valgus constraint and allows 15 degrees of internal/external rotation. The PS+ (PLUS Constrained) bearing provides a 2-degree varus/valgus constraint and restricts internal/external rotation to +/-2 degrees.
    When is the PS+ Tibial Bearing indicated for surgical use?
    The PS+ option is typically used in primary surgical situations where additional joint stability and initial constraint are required to resist rotation and varus/valgus lift-off.
    What materials are the SKII™ components manufactured from?
    The Femoral Condyles and Tibial Trays are made from durable Cobalt-Chromium-Molybdenum (CoCrMo) alloy, while the Tibial Bearings are manufactured from medical-grade Germany UHMWPE (Ultra-High-Molecular-Weight Polyethylene).
    How does the SKII™ system accommodate different stages of bone defects?
    The system features a seamless design that transitions from Normal Primary TKA to Complex Primary TKA using tibial augments and stems, and handles large central tibial defects with tibial cones and stems to reinforce prosthesis fixation.
    What is the advantage of the Same Platform Design?
    The Same Platform Design ensures compatibility across different components, allowing surgeons to address both standard primary and complex primary total knee arthroplasty (TKA) procedures efficiently.
    Where can I obtain detailed surgical instructions for this knee system?
    You can download the official "JUST MED Surgical Technique Manual for the SKII PS High Flexion Total Knee System" PDF directly from the Technology Education section on this page.