Leave Your Message
SKII PS/PS+ High Flexion Total Knee System - China Suppliers & Factory for Enhanced Stability and Flexibility
Hot Products

Product Details

SKII PS/PS+ High Flexion Total Knee System - China Suppliers & Factory for Enhanced Stability and Flexibility

● Intraoperative Flexibility
Our knee implant solutions available through trusted suppliers in China offer the choice between PS and PS+ tibial bearings, allowing for optimized stability during surgery.:

,

PS: This option presents no varus or valgus constraint, accommodating up to 15° of internal or external rotation.

,

PS+: This design restricts varus or valgus deviation to 2° and limits internal or external rotation to ±2° for enhanced control.

,

● Enhanced Stability
Featuring an innovative anterior dovetail design, our tibial bearing minimizes micromotion between the bearing and tibial tray, providing superior stability compared to competing products from other manufacturers.

,

● Osteolysis Risk Reduction
Our tibial tray incorporates a tapped bind hole, significantly reducing the risk of osteolysis due to wear. Our factory in China ensures these high-quality components meet rigorous standards, offering reliability in surgical settings.

    Special Description

    SKII PS+-1-2

    2 Options of Tibial Bearings

    Standard and PLUS

    • PS: No varus/valgus constraint
    • PS: 15 degrees internal/external rotation
    • PS+: 2 degrees varus/valgus constraint
    • PS+: +/-2 degrees internal/external rotation

    Used in a primary situation when more stability and initial constraint is desired to resist rotation and varus/valgus lift-off.

    SKII PS+-1-3

    Stem Extensions

    For optimal stress distribution

    Same Platform Design

    Meets requirements of both primary and complex primary TKA

    Augment Options

    Multiple specifications tibial augment for varying degrees or shapes of the tibial bone defect

    Product Features - Seamless System, Deal with Possible Bone Defects

    SKII PS+-2-2

    Normal Primary TKA

    SKII PS+-2-3

    Complex Primary TKA

    Tibial defect is treated with tibial augment; stem is required to protect the defect.

    SKII PS+-2-4

    Advanced Care

    Large central tibial defect is treated with tibial cone; stem is used to strengthen prosthesis fixation.

    Special Instrumentation

    SKII™ Femoral Condyle (PS)

    Material Spec (mm)
    CoCrMo 1# L 1# R
    2# L 2# R
    3# L 3# R
    4# L 4# R
    5# L 5# R
    6# L 6# R
    7# L 7# R
    8# L 8# R
    9# L 9# R
    SKII PSPS+ High Flexion Total Knee System (1)

    SKII™ Tibial Bearing (PS)

    Material Spec (mm) A/P (mm) M/L (mm)
    Germany UHMWPE 1# 10mm,12mm,14mm,16mm 38 59
    2# 10mm,12mm,14mm,16mm
    (for Tibial Tray 2#/3#)
    41/43 63/67
    4# 10mm,12mm,14mm,16mm
    (for Tibial Tray 4#/5#)
    46/48 71/75
    6# 10mm,12mm,14mm,16mm
    (for Tibial Tray 6#/7#)
    51/53 79/83
    SKII PSPS+ High Flexion Total Knee System (2)

    SKII™ Tibial Bearing (PS PLUS Constrained)

    Material Spec (mm) A/P (mm) M/L (mm)
    Germany UHMWPE 1# 10mm,12mm,14mm,16mm 38 59
    2# 10mm,12mm,14mm,16mm
    (for Tibial Tray 2#/3#)
    41/43 63/67
    4# 10mm,12mm,14mm,16mm
    (for Tibial Tray 4#/5#)
    46/48 71/75
    6# 10mm,12mm,14mm,16mm
    (for Tibial Tray 6#/7#)
    51/53 79/83
    SKII PSPS+ High Flexion Total Knee System (3)

    SKII™ Tibial Tray

    Material Spec (mm) A/P (mm) M/L (mm)
    CoCrMo 1# 38 59
    2# 41 63
    3# 43 67
    4# 46 71
    5# 48 75
    6# 51 79
    7# 53 83
    SKII PSPS+ High Flexion Total Knee System (4)

    Video Demonstration

    Technology Education

    SKII PS High Flexion Total Knee System Document Thumbnail
    JUST MED_Surgical Technique Manual_SKII PS High Flexion Total Knee System.pdf
    download button

    Frequently Asked Questions (FAQ)

    What are the primary differences between the SKII PS and PS+ Tibial Bearings?

    The SKII PS bearing offers standard function with no varus/valgus constraint and allows for a 15-degree internal/external rotation. The SKII PS+ bearing provides enhanced constraint with a 2-degree varus/valgus constraint and restricts rotation to +/-2 degrees for added stability.

    When is the SKII PS+ Constrained Tibial Bearing recommended for clinical use?

    The PS+ option is typically utilized in primary TKA situations where increased stability and initial constraint are required to effectively resist rotation and prevent varus/valgus lift-off.

    What materials are used to manufacture the SKII High Flexion Total Knee System?

    The Femoral Condyle and Tibial Tray are constructed from durable CoCrMo (Cobalt-Chromium-Molybdenum) alloy, while the Tibial Bearings are made from high-quality Germany UHMWPE (Ultra-High-Molecular-Weight Polyethylene) for excellent wear resistance.

    How does the SKII system handle varying degrees of tibial bone defects?

    The system features a Same Platform Design that accommodates multiple specifications of tibial augments, stem extensions for optimal stress distribution, and tibial cones to strengthen fixation in cases of large central defects.

    What sizing options are available for the SKII Femoral Condyle and Tibial Tray?

    The SKII Femoral Condyle (PS) is available in sizes 1# through 9# (with distinct Left and Right options). The SKII Tibial Tray is available in sizes 1# through 7# to accommodate a wide range of patient anatomies.

    Where can I obtain the surgical procedure manual for this knee system?

    You can download the official "JUST MED Surgical Technique Manual for the SKII PS High Flexion Total Knee System" directly from the Technology Education section on this page by clicking the download icon link.

    Leave Your Message