● Intraoperative Flexibility
Choose between PS or PS+ tibial bearings to enhance surgical stability for your patients:

,

PS: Offers no varus/valgus constraint and permits up to 15° of internal/external rotation, providing optimal flexibility during procedures.

,

PS+: Provides a moderate constraint with a 2° restriction on varus/valgus deviation and ±2° internal/external rotation, ensuring greater stability for specific patient needs.

,

● Enhanced Stability
Featuring an innovative anterior dovetail design, our tibial bearing minimizes micromotion between the bearing and tibial tray, surpassing competitors and delivering superior stability for your surgical operations.

,

● Osteolysis Risk Reduction
Our tibial tray includes a tapped bind hole, effectively lowering the risk of osteolysis from wear, making it a reliable choice for leading providers in China. As trusted suppliers and factory manufacturers, we ensure high-quality products tailored to meet the demands of modern orthopedic procedures.

    Special Description

    SKII PS+-1-2

    2 Options of Tibial Bearings

    Standard and PLUS

    • PS: No varus/valgus constraint
    • PS: 15 degrees internal/external rotation
    • PS+: 2 degrees varus/valgus constraint
    • PS+: +/-2 degrees internal/external rotation

    Using in a primary situation when more stability and initial constraint is desired to resist rotation and varus/valgus lift-off

    SKII PS+-1-3

    Stem Extensions

    For optimal stress distribution

    Same Platform Design

    Meets requirements of both primary and complex primary TKA

    Augment Options

    Multiple specifications tibial augment for varying degrees or shapes of the tibial bone defect

    Product Features-Seamless System, Deal with Possible Bone Defects

    SKII PS+-2-2

    Normal Primary TKA

    SKII PS+-2-3

    Complex Primary TKA

    Tibial defect is treated with tibial augment stem is required to protect the defect.

    SKII PS+-2-4

    Large central tibial defect is treated with tibial cone stem is used to strengthen prosthesis fixation.

    Special Instrumentation

    SKII™ Femoral Condyle (PS)
    Material Spec (mm)
    CoCrMo 1# L 1# R
    2# L 2# R
    3# L 3# R
    4# L 4# R
    5# L 5# R
    6# L 6# R
    7# L 7# R
    8# L 8# R
    9# L 9# R
    SKII PSPS+ High Flexion Total Knee System (1)
    SKII™ Tibial Bearing (PS)
    Material Spec (mm) A/P (mm) M/L (mm)
    Germany UHMWPE 1# 10mm,12mm,14mm,16mm 38 59
    2# 10mm,12mm,14mm,16mm
    (for Tibial Tray 2#/3#)
    41/43 63/67
    4# 10mm,12mm,14mm,16mm
    (for Tibial Tray 4#/5#)
    46/48 71/75
    6# 10mm,12mm,14mm,16mm
    (for Tibial Tray 6#/7#)
    51/53 79/83
    SKII PSPS+ High Flexion Total Knee System (2)
    SKII™ Tibial Bearing (PS PLUS Constrained)
    Material Spec (mm) A/P (mm) M/L (mm)
    Germany UHMWPE 1# 10mm,12mm,14mm,16mm 38 59
    2# 10mm,12mm,14mm,16mm
    (for Tibial Tray 2#/3#)
    41/43 63/67
    4# 10mm,12mm,14mm,16mm
    (for Tibial Tray 4#/5#)
    46/48 71/75
    6# 10mm,12mm,14mm,16mm
    (for Tibial Tray 6#/7#)
    51/53 79/83
    SKII PSPS+ High Flexion Total Knee System (3)
    SKII™ Tibial Tray
    Material Spec (mm) A/P (mm) M/L (mm)
    CoCrMo 1# 38 59
    2# 41 63
    3# 43 67
    4# 46 71
    5# 48 75
    6# 51 79
    7# 53 83
    SKII PSPS+ High Flexion Total Knee System (4)

    Video Demonstration

    Technology Education

    Surgical Technique Manual Cover
    JUST MED_Surgical Technique Manual_SKII PS High Flexion Total Knee System.pdf

    Frequently Asked Questions

    What are the key differences between the standard PS and PS+ Tibial Bearings?
    The standard PS bearing does not feature varus/valgus constraints and allows up to 15 degrees of internal/external rotation. In contrast, the PS+ (PLUS Constrained) bearing provides a 2-degree varus/valgus constraint and limits rotation to +/-2 degrees to offer enhanced mechanical stability.
    When is the SKII™ PS+ Constrained bearing recommended over the standard PS?
    The PS+ Constrained bearing is recommended for primary total knee arthroplasty (TKA) cases where greater joint stability and initial constraint are required to counteract rotation and resist varus/valgus lift-off.
    How does the "Same Platform Design" benefit TKA procedures?
    The Same Platform Design allows surgeons to seamlessly transition between primary and complex primary TKA. It accommodates various components (such as stem extensions and tibial augments) on a single platform without needing to change the base instrumentation system.
    What options does the SKII™ system offer for managing tibial bone defects?
    The system provides multiple specifications of tibial augments for varying defect shapes. For more complex scenarios, a tibial augment with a stem extension can protect the defect, while a tibial cone stem can be used to strengthen prosthesis fixation in large central tibial defects.
    What materials are used to manufacture the SKII™ implants?
    The Femoral Condyles and Tibial Trays are made from high-strength Cobalt-Chromium-Molybdenum (CoCrMo) alloy. The Tibial Bearings are manufactured using premium medical-grade Ultra-High-Molecular-Weight Polyethylene (UHMWPE) imported from Germany.